POWERFUL, EASY TO USE
The Radiation Analyzer - RAy™ Film Dosimetry Software provides everything necessary for completing detailed IMRT QA and other frequent QA tasks. For thousands less, RAy includes features not found in other leading film dosimetry software.
3D MULTI-SLICE VOLUMETRIC FILM/PLAN ANALYSIS
Import all available slices of the treatment plan, or select as many as needed to perform plan validation. Change from one slice to the next with one click of a button.
3D RENDERED VOLUMETRIC FILM/PLAN ANALYSIS
Import the 3D dose matrix from the treatment planning system and compare directly to 3D measured data acquired with a stacked film set.
MEASURED DVH/PLANNED DVH COMPARISON
Using 3D volumetric information perform a comprehensive quantitative analysis by generating and comparing measured DVH vs. planned DVH.
CYBER-KNIFE PATIENT-SPECIFIC QA
Compare both 2D or 3D film measurements to Cyberknife planning data. Cyberknife specific tools allow for fast registration based on tracking fiducials.
ELECTRONIC PORTAL IMAGING DEVICE (EPID)
Use EPID images or other filmless technology as input for filmless IMRT fluence validation.
MORE MEANINGFUL ANALYSIS
Add another dimension to your analysis by overlaying qualitative threshold isodose lines over quantitative information such as gamma, distance-to-agreement, percent dose difference, or DTA + % Dose Difference maps.
SAVE AND SHARE YOUR WORK
For each case, save data into one integrated .ray file so you can easily archive, retrieve, and share the complete case information with local or remote co-workers.
SAVE AND SHARE YOUR WORK
Unlimited support for the first year means answers are readily available when you need them.
Standard Features
The data acquisition process is greatly simplified by the integrated DICOM browser, and the support of all TWAIN compliant film digitizers.
Dose Mapping
-
Isodose
-
Dose Wash
-
Threshold Dose
-
% Dose Difference
-
Distance to Agreement
-
DTA+%Dose Difference
-
Gamma Analysis
-
Qualitative and Quantitative analyses overlay
-
BMP or JPG export of any analysis picture
Profiles and Gradients
-
Profile and Gradient
-
Symmetry and Flatness
-
Energy Check (PDD)
-
ASCII export of all 1-D analysis data
Profiles and Gradients
-
SRS Collimator Profile
-
SRS Collimator Output Factors
-
Small Electron Profile
-
Small Electron Cutout Factors
Other Tests
-
MLC Calibration Report for calibrating and maintaining calibrated leaf positions based on radiological leaf edge
-
Dynamic Wedge QA
-
Complementary Water Scans Module compares film results to benchmarked stored water scans.
-
Light vs. Radiation
-
Star Shot for radiation isocenter identification
Data Input
Film digitization is possible through all TWAIN compliant film digitizers including VIDAR® and Flat-Bed scanners; in 8, 12
and 16 bit.
Treatment planning data import is validated for the following planning systems:
-
Varian® Eclipse™
-
CMS® XiO®
-
Nucletron® TMS, THERAPLAN®, and Oncentra®
-
Philips® Pinnacle3®
-
Corvus®
-
BrainLAB®
-
Accuray® CyberKnife®
VIDAR® DosimetryPro Advantage® is a registered trademark of VIDAR Systems, Inc.
Oncentra™ is a trademark of Nucletron.
THERAPLAN® is a registered trademark of Nucletron.
CyberKnife® is a registered trademark of Accuray Incorporated.




